Comparison of temperature centers of EU ERP and US Energy Star

1035 2022-04-29

EU ERP, US Energy Star, LM-80, ERP2, color tolerance, step 3, step 5, EPREL

In the white LED light distinguish, the market mainly uses the European Union ERP and American Energy Star two kinds of light beam standards,Because of the difference in the center point of the two spectral standards, so in the spectral, we must choose the standard and center point used。  Below we made a comparison of the X/Y axis center points of the two spectral standards for your reference:

EU ERP and US Energy Star center point comparison
The center point of the U.S. Energy Star The center point of the EU ERP
Standard points X Y Standard points X Y
ANSI_F2700 0.4578 0.4101 IEC_F2700 0.4630 0.4200
ANSI_F3000 0.4338 0.4030 IEC_F3000 0.4400 0.4030
ANSI_F3500 0.4073 0.3917 IEC_F3500 0.4090 0.3940
ANSI_F4000 0.3818 0.3797 IEC_F4000 0.3800 0.3800
ANSI_F4500 0.3611 0.3658 / / /
ANSI_F5000 0.3447 0.3553 IEC_F5000 0.3460 0.3590
ANSI_F5700 0.3287 0.3417 / / /
ANSI_F6500 0.3123 0.3282 IEC_F6500 0.3130 0.3370